Test that allows you to simulate the extreme conditions of use of Temperature and Pressure, stressing the component with fatigue. The test is generally performed by using a working fluid such as glycol/water or air. The performance characteristics of the pulsating pressure bench are as follows: Maximum pressure: 16 bar; Maximum flow: about 80 liters /min; Maximum Pulse Frequency: 1Hz; Max fluid temperature: 150°C; Environmental temperature: -70°C÷ 180°C through coupling to climatic chamber; Waveform: Trapezoidal/Sinusoidal
It is also possible to combine the pulsating pressure bench with the vibration bench and the climatic chamber to carry out tests with the simultaneous presence of temperature-pressure-vibration.